Datasheet

Size : 4/3FA
4500mAh
4100mAh
1.2V
Fast Charge
2)
3000mA x about 1.6h
Charge
Condition
Fast Charge
2)
C - 40°C
C - 50°C
Less than
30days
-20°C - 50°C
Less than
90days
-20°C - 40°C
Less than
1year
-20°C - 30°C
Approx. 62 g
18.0(D) x 67.5(H) mm
Typical Characteristics
Charge
Discharge
2010/03
Dimensions
(with tube)
Specifications
Cell Type HR-4/3FAU
Charge : 450mA×16h, Discharge : 900mA(E.V.=1.0V) at 20°C
Nominal Voltage
Discharge Condition
Weight
4)
Size
4)
:(Diameter) x (Height)
Type : Nickel-Metal Hydride Battery
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Charging Current x Time
D
H
18.0 mm
67.5 mm
2)Use recommended charging system.
4)With tube.
1)Single cell capacity under the following condition.
67.5 mm
Ambient Temp.
Storage
Condition
18.0 mm
Capacity
1)
Typical
Minimum
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0 1000 2000 3000 4000 5000
Discharge Capacity (mAh)
Cell Voltage (V)
Charge : 3000mA(-V=10mV)
Rest : 1h
Discharge : 900mA, 4500mA,9000mA (E.V.=1.0V)
Ambient Temp. : 20°C
900mA 9000mA
4500mA
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
0 20 40 60 80 100 120
Charge Time (min)
Cell Voltage (V)
Charge : 3000mA (-V=10mV)
Ambient Temp. : 0°C,20°C,40°C
C
20°C
40°C
Approx. 20m(at 1000Hz)