Energy Guide

©2018 Trinity Glass International, Inc.
SHGC
0.01
SHGC
0.01
LBETMXXX08/2018
ENERGY PERFORMANCE RATINGS
U-Factor
1
/ Solar Heat Gain Coefficient
(
SHGC
)
Individual Option Number
Product
Description**
Default Frame***
Wood
PVC Frame
3/A5/na/AIR/0.313
Flush / Embossed
01233-00001
Air Leakage 0.3 cfm/ft
2
1/4 Lite
410†
1/2 Lite
900†
3/4 Lite
1100†
Full Lite
>1100†
3/A5/na/AIR/0.313
0.08
0.20
01234-00001
0.08
0.20
01311-00001
0.13
0.23
01272-00001
0.13
0.23
01349-00001
Manufacturer stipulates that these ratings conform to applicable NFRC procedures for determining whole
product performance. NFRC ratings are determined for a fixed set of environmental conditions and a
specific product size. NFRC does not recommend any product and does not warrant the suitability of any
product for any specific use. Consult manufacturer’s literature for other product performance information.
* Numbers below the performance ratings are referenced in the NFRC Certified Products Directory
(e.g., ABC-X-1-00001-00001 or 123-X-1-00001-00001)
** #glazing layers / spacer type / low-e emissivity (surface) / gap fill / gap width (na=not applicable)
*** per NFRC 100 † square inches
1
btu/hr*ft
2
*F
www.nfrc.org
PVC Frame
3/A5/na/AIR/0.313
(Center Arch)
3/A5/na/AIR/0.313
(Center Arch)
0.08
0.20
01253-00001
0.08
0.20
01330-00001
Mahogany Fiberglass Door
In-swing (IS) and Out-swing (OS)
TGI-M-7*
U-Factor
1
0.15
U-Factor
1
0.15
PVC Frame
Flush / Embossed
01310-00001
SHGC
0.01
LBETPXXX08/2018
ENERGY PERFORMANCE RATINGS
U-Factor
1
/ Solar Heat Gain Coefficient
(
SHGC
)
Individual Option Number
Product
Description**
Default Frame***
Wood
PVC Frame
3/A5/na/AIR/0.313
Flush / Embossed
01648-00001
Air Leakage 0.3 cfm/ft
2
1/4 Lite
410†
1/2 Lite
900†
3/4 Lite
1100†
Full Lite
>1100†
3/A5/na/AIR/0.313
0.07
0.19
01648-00001
0.07
0.20
01702-00001
0.13
0.23
01659-00001
0.13
0.23
01712-00001
0.18
0.25
01673-00001
0.18
0.25
01726-00001
0.24
0.28
01687-00001
0.24
0.28
01740-00001
Manufacturer stipulates that these ratings conform to applicable NFRC procedures for determining whole
product performance. NFRC ratings are determined for a fixed set of environmental conditions and a
specific product size. NFRC does not recommend any product and does not warrant the suitability of any
product for any specific use. Consult manufacturer’s literature for other product performance information.
* Numbers below the performance ratings are referenced in the NFRC Certified Products Directory
(e.g., ABC-X-1-00001-00001 or 123-X-1-00001-00001)
** #glazing layers / spacer type / low-e emissivity (surface) / gap fill / gap width (na=not applicable)
*** per NFRC 100 † square inches
1
btu/hr*ft
2
*F
www.nfrc.org
Premium Fiberglass Door
In-swing (IS) and Out-swing (OS)
TGI-M-3*
U-Factor
1
0.15
U-Factor
1
0.16
SHGC
0.01
PVC Frame
Flush / Embossed
01701-00001
ENERGY RATINGS
Feather River NFRC Labels