Product Overview
ES-F-LF860L
MasterSeries
®
LF860
Reduced Pressure Zone
Backflow Prevention Assemblies
Size: 2
1
⁄2" - 10" (65mm - 250mm)
LEAD FREE
*
For Non-Health Hazard Applications
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
–––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold.
Series LF860 Reduced Pressure Zone Assembly
The FEBCO MasterSeries LF860 Reduced Pressure Zone
Assembly is specifically designed to protect against possible
backpressure and backsiphonage conditions for high hazard [i.e.,
toxic] application in accordance with Local Governing Water Utility
Code. This Backflow Prevention Assembly is primarily used on
potable drinking water systems where Local Governing Code
mandates protection from non-potable water being pumped or
siphoned back into the potable water system.
The LF860 features Lead Free* construction to comply with low
lead installation requirements. The Lead Free* Reduced Pressure
Zone Assemblies shall comply with state codes and standards,
where applicable, requiring reduced lead content.
Features
• Inline Serviceable Assembly
• No Special Tools Required for Servicing
• Captured Modular Spring Assembly
• Reversible & Replaceable Discs
• Field Replaceable Seats
• Ductile Iron Valve Body Design
• Stainless Steel Check Components
• Modular Pressure Differential Relief Valve
• Repairable Pressure Differential Relief Valve
• Clapper Check Assembly
• Captured O-ring Design
Specifications
The FEBCO MasterSeries LF860 Reduced Pressure Zone
Assembly shall be installed on the potable water supply and at
each point of cross-connection to protect against possible back-
pressure and backsiphonage conditions for high hazard [i.e.,
toxic] applications. The assembly shall consist of a main line valve
body composed of a pressure differential relief valve located in
a zone between two (2) independently acting approved clapper
style check modules with replaceable seats and disc rubbers.
Servicing of the pressure differential relief valve and both check
modules does not require any special tools; both check mod-
ules are accessed through independently top entry covers. This
assembly shall be fitted with AWWA Compliant inlet/outlet resilient
seated shutoff valves; when used on a Fire-Sprinkler application,
the assembly shall be fitted with approved UL/FM inlet/outlet
resilient seated shutoff valves and contain four (4) properly located
resilient seated test cocks as specified by AWWA Standard C511.
Flow and pressure loss performance parameters shall meet the
requirements of AWWA Standard C511.
*The wetted surface of this product contacted by consumable
water contains less than 0.25% of lead by weight.
NOTICE
Inquire with governing authorities for local installation requirements
NOTICE
The information contained herein is not intended to replace the
full product installation and safety information available or the
experience of a trained product installer. You are required to
thoroughly read all installation instructions and product safety
information before beginning the installation of this product.