User Manual
Table Of Contents
Trouble shooting
Item Reason Maintenance
System not working
A、Not plugged in or not turned on
Connect the power, or turn the power switch to
the "NO" position
B、Security key not in place
Put the safety key in the correct position
C 、 No power to the controller or
monitor
Replace the controller or monitor
D、Poor cable connection
C
heck system input and output cable terminals
and
communication cables inside stand post
Sudden stop in normal
state
A、Safety key off
Replace the safety key
B、System abnormal
Please call after-sales service
Button failure Button invalid
1. Replace the key board and the keyboard
cable;
2. Replace the PCB board
3. Replace the monitor.
E-01
A、Poor communication line
Reconnect the communication cable and check
if the terminal is connected well or replace the
communication cable
B、defective console
Replace the console
C、defective controller
Replace the controller
E-02
A
、
Defective motor cable and motor
Replace the motor
B、 Poor connection between motor
cable and controller or defective
controller
Check and connect cables well or replace the
controller
E-03
A、The speed sensor is not installed
correctly
Check and reconnect
B、Defective speed sensor
Replace the speed sensor
C 、 Dirty speed sensor or poor
contact
C
heck and reconnect/clean the dust, grease on
s
peed sensor
D、defective controller
Replace the controller
E-05
A、Controller is damaged
Replace the controller
B、damaged motor
Replace the motor
C、mechanical failure
Check whether the silicon oil backside of
running belt is dry or rollers was blocked
E-07
Console does not detect safety lock
signal
1. Check whether the safety key is in correct
position; 2. Reinstall the safety key sock; 3.
Replace the console
No heart rate display
A、T
he handle pulse cables are not
i
nserted properly or defective
Check and connect or replace the handle pulse
cables
B、monitor cables are defective
Replace the console
The console shows
incomplete or missing
strokes
A、LED digital tube is defective
Replace the PCB board or monitor
B、system error
Replace the monitor
lift failure
A、Defective incline motor
Replace the incline motor
B、defective controller
Replace the controller
C、Controller signal is abnormal
Press the calibrate key on the controller to
calibrate the incline value.
29