Item Reason Maintenance
System not working
ANot plugged in or not turned on
Connect the power, or turn the power switch to
the "NO" position
BSecurity key not in place
Put the safety key in the correct position
C No power to the controller or
monitor
Replace the controller or monitor
DPoor cable connection
C
heck system input and output cable terminals
and
communication cables inside stand post
Sudden stop in normal
state
ASafety key off
Replace the safety key
BSystem abnormal
Please call after-sales service
Button failure Button invalid
1. Replace the key board and the keyboard
cable;
2. Replace the PCB board
3. Replace the monitor.
E-01
APoor communication line
Reconnect the communication cable and check
if the terminal is connected well or replace the
communication cable
Bdefective console
Replace the console
Cdefective controller
Replace the controller
E-02
A
Defective motor cable and motor
Replace the motor
B Poor connection between motor
cable and controller or defective
controller
Check and connect cables well or replace the
controller
E-03
AThe speed sensor is not installed
correctly
Check and reconnect
BDefective speed sensor
Replace the speed sensor
C Dirty speed sensor or poor
contact
C
heck and reconnect/clean the dust, grease on
s
peed sensor
Ddefective controller
Replace the controller
E-05
AController is damaged
Replace the controller
Bdamaged motor
Replace the motor
Cmechanical failure
Check whether the silicon oil backside of
running belt is dry or rollers was blocked
E-07
Console does not detect safety lock
signal
1. Check whether the safety key is in correct
position; 2. Reinstall the safety key sock; 3.
Replace the console
No heart rate display
AT
he handle pulse cables are not
i
nserted properly or defective
Check and connect or replace the handle pulse
cables
Bmonitor cables are defective
Replace the console
The console shows
incomplete or missing
strokes
ALED digital tube is defective
Replace the PCB board or monitor
Bsystem error
Replace the monitor
lift failure
ADefective incline motor
Replace the incline motor
Bdefective controller
Replace the controller
CController signal is abnormal
Press the calibrate key on the controller to