User's Manual

OBID
®
classic-pro INSTALLATION ID CPR30-USB
FEIG ELECTRONIC GmbH Page 6 CPR30-Manual.doc
Technische Daten / Technical Data
Gehäuse / Housing Plastic (Housing ASA-PC / Front: acrylic glass)
Abmessungen / Dimensions 144 x 84 x 18 mm (5.69 x 3.30 x 0.71 in)
Farbe / Color white body with black front
Gewicht / Weight 105 g
Schutzart / Protection Class IP 42
Temperaturbereich /
Temperature Range
Betrieb / Operation
Lagerung / Storage
-20 °C to +60 °C
-40 °C to +85 °C
Relative Luftfeuchte / Relative Air Humidity 95 % (non-condensing)
MTBF 500.000 h
Spannungsversorgung / Supply Voltage
5V ϑ USB bus powered
Stromaufnahme / Current Consumption max. 230 mA
Host Interface USB Full-Speed (12 Mbit/s)
Optische Anzeigen / Optical Indicators
LED green: power and online / offline
LED orange: Transponder communication
Akustische Anzeigen / Acoustic Signaler
Beeper
EEPROM (for Parameter) 512 Byte (1 * 10
6
write cycles)
FLASH (for Firmware) Firmware update in Application possible
Antenne / Antenna Internal
Betriebsfrequenz / Operating Frequency 13.56 MHz
RF-Sendeleistung / RF- transmitting power 100 mW
Datenrate / Datarate: ISO 14443-A: 106 kBit/s
ISO 14443-B: 106...848 kBit/s
RF Interface
ISO15693
ISO14443-A & ISO14443-B
- 106 kbit/s
- part 4 fully supported
Unterstützte Transponder
Supported Transponder
mifare classic, SLE44R35S (UID only)
e.g.: ICode SLI, Tag-It HFI, my-d vicintiy,
STM LRI512, mifare
®
UltraLight,
mifare
®
DESfire, mifare Plus (SL0, SL3)
Smart MX, SLE44R35S, SLE66CL, ST19XR34,
etc.
NFC: Type 2 and Type 4 in read/write and NFC
card emulation mode
Betriebsarten / Operating modes Polling-Mode