User's Manual

4 Mechanical Integration
Page 10 of 38
Label
Description
Intended Use
1
Hinged Cover
See Table 4
2
Buzzer
The buzzer is used to signal events to the user
Table 3: Back side elements
Fig. 5: cVEND PIN elements under the hinged cover
Label
Description
Inteded Use
1
Service Mode Switch T1
Activation of service and setup menu by service technician
2
LED1 Operation Indicator
Service indicator shows different operation states of cVEND PIN
controlled by the application
3
LED2 MDB Indicator
Indicates if the MDB controller is running
4
5
SAM Socket 1 (S1)
SAM Socket 2 (S2)
SAMs under application control e.g. public transport or other use
cases
Table 4: Elements under the hinged cover
4 Mechanical Integration
Mechanical Integration
For flush integration into a front panel the cVEND PIN has to be placed in a corresponding cutout and has to
be pressed against the front plate by screwing on the four screwing points provided for this purpose. For
fastening threaded bolts M4 x 12 mm are recommended. The maximum tightening torque is approx. 2,5 Nm.
NOTE:
The PIN Entry function is available after terminal set up (see Removal Protection Activation) only if
both removal protection switches (S1, S2) are activated during installation.
Fehler! Verweisquelle konnte nicht gefunden werden. shows the recommended front panel cut-out.