User's Manual
Table Of Contents
- Annex no. 5 (Functional Description - User Manual).pdf
- M90113-10e-PY-B.pdf
- 1 Warnings – Read Before Start-Up!
- 2 Characterization
- 3 Functional Elements
- 4 Mechanical Integration
- 5 Connectors
- 5.1 Connector X1 – Power Supply and MDB Interface
- 5.2 Standby Mode / Wake-Up
- 5.3 Connector X2 – USB Device Interface
- 5.4 Connector X3 – COM 0 (RS232 V.24 Interface)
- 5.5 Connector X4 – USB Host 2 Interface
- 5.6 Connector X5 – Ethernet Interface
- 5.7 Connector X6 - Auxiliary
- 5.8 Connector X7 – USB Host 1
- 5.9 Connector X8 – cVEND SHCR
- 5.10 Connector X9 – COM 2 (RS232 V.24)
- 5.11 SAM Sockets (S1, S2)
- 6 Installation and Setup
- 7 Maintenance and Cleaning
- 8 User Interface
- 9 Technical Data
5 Connectors
Page 17 of 38
5 Connectors
Connectors
The connector I/O PINs are described from the cVEND PIN view. A cVEND PIN input must be connected to
one output or vice versa.
5.1 Connector X1 – Power Supply and MDB Interface
Pin
Label
Direction
1
Power Supply – V
CC
(12 to 42 V DC)
-
2
Power Supply – GND
-
3
Wake-Up (see X.X Standby Mode / Wake-Up)
I/O
4
MDB Master Receive
O
5
MDB Master Transmit
I
6
MDB Communication Common
-
Table 5: Pin Assignment MDB Connector (X1)
Required Connector:
The fitting complement for this connector consists of a 6-pole plug type Molex Mini Fit and the appending
crimp contact.
Manufacturer Ordering Code:
• Molex 39-01-2060
Plug 6-pole, grid dimension 4.2 mm, 2-rowed, Molex Mini Fit housing
• Molex 39-00-0065
Crimp contact, female, grid dimension 4.2 mm, AWG#22-28, Molex Mini Fit
NOTE:
• The Device has to be supplied by a limited power supply according EN 62368-1 Chapter Q.1 or
with a NEC Class 2/LPS certified power supply.
• Supply voltages outside the specifications may destroy the device.
• Each Device has to be supplied by a separate external power supply.
• External wiring for the power supply must be compliant with
- IEC 60332-2-1 and IEC 60332-2-2 for Wire Cross Section < 0,5 mm
2
- IEC 60332-1-2 and IEC 60332-1-3 for Wire Cross Section > 0,5 mm
2
• All cables must be fed through a ferrite as close as possible to the device (impedance greater
than 700 ohms @ 800 MHz, e.g. Würth Elektronik 7427154). Cables can be bundled for
feedthrough.
Fig. 10: Connector X1 – Power/MDB