User's Manual
Table Of Contents
- Annex no. 5 (Functional Description - User Manual).pdf
- M90113-10e-PY-B.pdf
- 1 Warnings – Read Before Start-Up!
- 2 Characterization
- 3 Functional Elements
- 4 Mechanical Integration
- 5 Connectors
- 5.1 Connector X1 – Power Supply and MDB Interface
- 5.2 Standby Mode / Wake-Up
- 5.3 Connector X2 – USB Device Interface
- 5.4 Connector X3 – COM 0 (RS232 V.24 Interface)
- 5.5 Connector X4 – USB Host 2 Interface
- 5.6 Connector X5 – Ethernet Interface
- 5.7 Connector X6 - Auxiliary
- 5.8 Connector X7 – USB Host 1
- 5.9 Connector X8 – cVEND SHCR
- 5.10 Connector X9 – COM 2 (RS232 V.24)
- 5.11 SAM Sockets (S1, S2)
- 6 Installation and Setup
- 7 Maintenance and Cleaning
- 8 User Interface
- 9 Technical Data
5 Connectors
Page 26 of 38
5.9 Connector X8 – cVEND SHCR
Connector X8 is a COM port which is the connector for Secure Hybrid Card Reader cVEND SHCR. The
related connection cable is included in the scope of delivery of cVEND SHCR.
Pin
Label
Direction
1
CTS
-
2
RxD
I
3
RTS
I
4
TxD
O
5
GND
-
6
V
CC
SHCR
O
Table 11: Pin Assignment SHCR Connector (X8)
Fig. 21: Connector X8 – SHCR Connector