User's Manual

OBID i-scan
Installation ID ISC.ANT.MUX
FEIG ELECTRONIC GmbH Page 32 of 37 M30201-1de-ID-B.doc
E N G L I S H
9.3. Jumpers JP1- 8
Jumpers 1-8 can be used to assign the corresponding outputs OUT1-8 to the inputs IN1 and IN2
(see Figure 8).
Figure 8: Assigning of output OUTx
The jumper position has no meaning for outputs which are not used. Table 6 shows two examples:
Table 6: Examples for jumper settings JP1-8
Jumper setting Assignment
Jumpers JP1-8 are all at position 2-3.
All outputs (OUT1-8) are then assigned to input IN1.
Jumpers JP1-4 are at position 2-3, jumpers JP5-8 at
position 1-2.
This assigns outputs OUT1-4 to input IN1 and
outputs OUT4-8 to input IN2.
JP1, JP3, JP4 and JP6 are at position 2-3; JP2, JP5
and JP7 at position 1-2
This assigns outputs OUT1, 3, 4, 6 to input IN1 and
outputs OUT2, 5, 7 to input IN2. Output OUT8 is not
assigned to an input.
JPx
OUTx
IN1
IN2