User's Manual

OBID i-scan
Installation ID ISC.ANT.MUX
FEIG ELECTRONIC GmbH Page 33 of 37 M30201-1de-ID-B.doc
E N G L I S H
9.4. Jumpers JP11 - JP18
With the Jumpers JP11 – JP18 a DC-Offset of + 7V is switched on to the according output OUT1 –
OUT8. The maximum DC-current for one output is 100mA.
9.5. Jumpers JP19 and JP20
Jumpers JP19 and JP20 are used to set the input resistance for the opto-coupler input on X2.
Table 1 (Section 8.4. X2: Input (Opto-Coupler)) lists the possible settings.