User's Manual

OBID i-scan
®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 30 of 42
M50101-2de-ID-B.doc
E N G L I S H
10 Startup
The ID ISC.ANT800/600-DA is placed in service using a simple configuration consisting of a
Reader and an antenna. To tune the antenna a DC voltage supply is needed for the antenna tuner.
The supply voltage as well as the HF signals are carried on the coax cable.
The ID ISC.LR2500 Reader used in the example is able to provide an antenna with DC voltage.
Other ways of powering an ID ISC.DAT antenna tuner can be found in the corresponding
installation guide (M40401-xde-ID-B).
10.1 Required components
The following components are needed for the configuration described above:
- Reader ID ISC.LR2500 Type -A or -B
- Antenna ID ISC.ANT800/600-DA
The cables on the ID ISC.ANT800/600-DA antenna are each approx. 3,60m long.
To get the optimal performance at the setup with one antenna and one Reader ID ISC.LR2500 the
antenna cable should be changed to a 1,35m cable. So you need:
- ID ISC. ANTC135 Antenna cable 1,35m
For longer distances between Reader and antennas the ID ISC.ANT.EC extension can be used to
extend the antenna cable by 7.20m. This will result in slight loss of sensitivity.
For extending the cable you will need:
- ID ISC.ANT.EC
For startup the service software
- ISOStart Version 9.01 or higher
on a personal computer running under Microsoft
®
Windows
®
is required. The service can be
downloaded at the Download Area of the Homepage www.feig.de.