User's Manual

OBID i-scan
®
Installation
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Page 34 of 42
M50101-2de-ID-B.doc
E N G L I S H
Step
Procedure
Note
9
Set by clicking on „Apply“.
10
Transponder:
Configure the parameter as
following:
„Driver“ Select: ISO 15693
Enable: „Anticollision“
„PersistenceResetTime“
20 x 5 ms
„No of Timeslots“ –
1 timeslot
„Data Coding“ – 1 of 4
„AFI“ – Disabled
11
Set by clicking on „Apply“.
12
Operating Mode:
To tune, activate „ISO-Host
Mode“
13
Set by clicking on „Apply“.
14
Select „Commands“ menu
15
Select „Start Tuning“ for
Tuner Address 1.
The tuning procedure may
take up to 30s.
16
Check tuning results by
using „Get Antenna
Values“.
17
If Tuning Status is not „OK“ repeat Step 15 & 16.