Figure 11 Top few tuning board with default Jumper positions
The following table has been made up in order to facilitate the process of tuning or re-tuning.
The jumper positions may be used as a first start or reference values, only. In any case, the im-
pedance or VSWR must be double checked, afterwards. And a matching of the optimised working
point / jumper configuration is necessary.
Table 1: Jumper position
Distance to metal
(plate)
Jumper closed at Pin No
J1 J2 J3
2,5 cm 5-6,7-8,9-10,11-12 5-6,7-8,9-10,11-12 3-4,9-10,13-14,15-16,17-18
5 cm 3-4,5-6,9-10,11-12 3-4,5-6,9-10,11-12 9-10,15-16, 17-18
7,5 cm 5-6,9-10,11-12 5-6,9-10,11-12 3-4,7-8,9-10,11-12,13-14,17-18
10 cm 3-4,7-8,11-12 3-4,7-8,11-12 1-2,3-4,7-8,11-12,13-14,17-18
15 cm 3-4,7-8,11-12 3-4,7-8,11-12 11-12,13-14,17-18
20 cm 3-4,7-8,11-12 3-4,7-8,11-12 3-4,7-8,9-10,13-14,17-18
25 cm 3-4,7-8,11-12 3-4,7-8,11-12 7-8,9-10,13-14,17-18
30 cm 3-4,7-8,11-12 3-4,7-8,11-12 1-2,3-4,5-6,9-10,13-14,17-18
35 cm 3-4,7-8,11-12 3-4,7-8,11-12 1-2,3-4,5-6,9-10,13-14,17-18
40 cm 3-4,7-8,11-12 3-4,7-8,11-12 1-2,3-4,5-6,9-10,13-14,17-18
Without metal
(plate)
3-4,7-8,11-12 3-4,7-8,11-12 1-2,3-4,5-6,9-10,13-14,17-18
The default configuration are the jumper position in the row “without metal (plate)”!