• Shock
EN60068-2-27
Acceleration : 20m/s
2
(~ 30 g)
Applicable standards
• EMV
EN 300 683
• Safety
EN 60950
*Size Transponder coil 46 x 75 mm
2
,
,
over the centre of the antenna, sensitivity / minimum operat-
ing field H
min
=70mA/m rms, parallel orientation to the antenna,. transmitting power 4 /8 W.
**In connection with the reader ID ISC.LRM2000 and according the regulations EN 300 330 and
ERC Recommendation 70-03 Annex 9 Vol. F1. See Chapter Fehler! Verweisquelle konnte nicht
gefunden werden.
6.1 Approval
6.1.1 Europe (CE)
When properly used this radio equipment conforms to the essential requirements of Article 3 and
the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.
Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2
The technical data of the ID ISC.LRM2000 Reader built into the ID ISC.ANT1690/600-A an-