5.2.2 Configuration of a Gate Antenna with Multiplexer
Connect the components as shown in Fig. 9. Almost, all cable should be mounted already.
Normally, the antenna cable from antenna Type B has to be connected to OUT2 at the multiplexer
and the cable of the signal light of antenna Type B has to be connected to GND and terminal 5 of
the terminal block at antenna Type A, only.
Fig. 9: Connecting the components for a gate consisting of two antennas, reader and multiplexer
-
Alarm Light
+
Buzzer
GND
+24VDC
DC Power
Supply 24V
X2
X3
0,85m+7,20m
2 Tuning boards of the
antenna ID ISC.ANT1690/600
Multiplexer
ID ISC.ANT.MUX.M4
Long Range Reader
ID ISC.LRM2000-
A
X1
0,50m
IN1
OUT
OUT
X1
Torrid core
X9, Pin1+3
0,85m