Installation Manual

OBID i-scan
®
Installation ID ISC.ANT1690/600-A/-B
FEIG ELECTRONIC GmbH Page 24 of 41 M91200-1e-ID-B.doc
5.2.6 Tuning the Gate Antenna with Multiplexer
Before tuning the gate antenna, you must quit the ISOStart software. Then the gate can be tuned
as follows:
Step Action Note
1
Start “DATuningTool” software
2
Select “Detect Reader...”.
In the „Detect Reader“ window
select the interface (COM-Port
1, BusAdr. 0) and then click
on “Detect”.
3
Use „Settings“ to enter the
configuration:
Single Mode,
Number of Antennas 2
Click on “with Multiplexer“
Number of Tuning Iterations 3
4
Activate „Start Tuning“ and
wait until the tuning process is
finished.
5
The tuning status is displayed
after each tuning pass.
After successful tuning both
antennas are shown in green.
6
If this does not succeed on
the first try, start the process
again by clicking on „Start
Tuning“
After successful tuning, close the DATuningTool.