5.5 Activating the Automatic Mode
The gate must be used in one of the Automatic Modes (Buffered Read, Notification
or Scan Mode) to get a maximum performance. Otherwise the reading performance
will be significantly reduced.
For more information, see System Manual H60700-2e-ID-B.pdf ID ISC.LRM2000-A/B
In the automatic modes, the tags are read at maximum speed and the information is stored in the
ring buffer of the reader. Data set can be read by the host.
Due to the automatic alarm features at the automatic mode, the reader/gate can run without any
interface connection (Serial, Ethernet).
To activate „Buffered Read Mode“ proceed as follows:
Step Action Note
1
Select „Configuration“
2
Operation Mode:
„Mode“ - Buffered Read
Mode
„Data Selector“
-UID
-Antenna No
-Time
-Date
„Filter“
Set Transponder Valid
Time.
(e.g. 55 x 100ms)
3
Set clicking on „Apply“
Note:
The configuration of the Notification or Scan Mode are similar
To test the function of the Gate in the Buffered Read Mode, the BRM Window of ISOStart or the
BRMDemo program can be used.