Installation Manual

OBID i-scan
®
Installation ID ISC.ANT1690/600-A/-B
FEIG ELECTRONIC GmbH Page 38 of 41 M91200-1e-ID-B.doc
Ambient Conditions
Temperature range
– Operating
– Storage
–25°C to +50°C
–25°C to +70°C
Applicable Standards
RF approval
– Europe
– USA
EN 300 330
FCC Part 15
EMC EN 301 489
Safety
– Low Voltage Directive
– Human Exposure
UL 60950-1
EN 50364
* Persistent deformation after load release approx. 1 cm.
** Qty. 2 ID ISC.ANT1690/600-A/-B antennas, antenna spacing (antenna center), same flow
direction, Tag 46 mm x 75 mm ISO15693, sensitivity / minimum field strength H
min
=60 mA/m rms,
transmitting power 8 W, tag orientation parallel to antenna for horizontal movement through the
antenna. The detection performance also depending of the strength of the Transponder answer
signal!
*** Tag 46 mm x 75 mm ISO 15693, sensitivity / minimum field strength H
min
=60 mA/m rms,
transmitting power 8 W, aligned in all 3 dimensions for horizontal movement through the antenna.