OBID i-scan
®
Installation ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH Page 16 of 40 M91201-0e-ID-B.doc
4.2.2 Configuration of a Gate antenna with Multiplexer
Connect the components as shown in Fig. 9. Almost, all cable should be mounted already.
Normally, the antenna cable from antenna Type B has to be connected to OUT2 at the multiplexer
and the cable of the signal light of antenna Type B has to be connected to GND and terminal 5 of
the terminal block at antenna Type A, only.
Fig. 9: Connecting the components for a gate consisting of two antennas, reader and Multiplexer
-
A
larm Light
+
Buzzer
DC Power-
Supply 24V
X2
X3
3,62m
2 Tuning boards of the
antenna ID ISC.ANT1700/740
Multiplexer
ID ISC.ANT.MUX.M4
Long Range Reader
ID ISC.LRM2000-
A
X1
1,35m +
3,6
2m
IN1
OUT1
OUT2
X1
Torrid core
X9, Pin1+3
3,62m
GND
+24VDC