Installation Manual

OBID i-scan
®
Installation ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH Page 19 of 40 M91201-0e-ID-B.doc
4.2.4 Setting the Antenna Tuner
To check the settings of the antenna tuner the antenna has to be opened. For that, remove the
two fastening screws (hexagon socket width A/F2,5) at the antenna base cover and move it
upwards. Fig. 12
Step 1 Step 2
Fig. 12: Opening of the antenna base
The ID ISC.ANT1700/740 antennas are factory set as follows:
Table 3: Jumper settings for Antenna Tuner
Function Jumper Position
1 Q resistor
JP1 open
2 Q resistor
JP2 closed
Antenna switch JP3 closed
Capacitor C1 JP 11,12,13,14 open
Capacitor C2 JP 21,22
JP 23,24,25,26
Open
closed