Installation ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH Page 21 of 40 M91201-0e-ID-B.doc
4.2.5 Reader Configuration with Multiplexer
To tune the antennas, open the ISOStart software and read out the current configuration of the
Reader:
Step Action Note
1
Start ISOStart Software
2
Select „Detect“
3
Select „Keep Configuration
unchanged and exit Wizard“
and click on „Exit“
This has to be done at each
start of ISO-Start program
otherwise the configuration
of the reader will be
changed.
4
Select „Options => Program“