Installation Manual
Table Of Contents
OBID i-scan
®
Installation ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH Page 23 of 40 M91201-0e-ID-B.doc
Then set the operating power, Transponder Parameters and ISO Host Mode:
Step Action Note
1
Select “Configuration”
2
Air Interface:
“RF-POWER” (here 8W)
„Mulitplexer Enable“
„1 Input (Single Mode)“
„No of Output Channels „
(e.g. 2)
„Antenna Active Time“
100 x 5ms
3
Set by clicking on „Apply“.
4
Transponder:
Configure the parameters as
follows:
• „Driver“ – here ISO 15693
• „Anticollision“ – enable
• „No of Timeslots“ –
1 timeslot
• „Data Coding“ – 1 of 4
• „AFI“ – Disabled
Note: National RF regulations may require different
settings. 4.6 Configuring the Reader in accordance with
national RF regulations
5
Set by clicking on „Apply“.
6
Operating Mode:
For antenna tuning the reader
must be set to „Host Mode“.
7
Set by clicking on „Apply“.