Installation Manual

OBID i-scan
®
Installation ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH Page 25 of 40 M91201-0e-ID-B.doc
4.3 Testing the Gate Antenna
After tuning the gate antenna, you can check for proper function using a Reader, the ISOStart
service software and a Transponder. Here the Noise Level and performance of the gate are tested.
4.3.1 Checking the Noise Level
Step Action Note
1
Select „Function Unit
Command“ „Multiplexer“
„Channel Select“ activate
antenna 1.
„Cascade Level = 1“
„Output Channel of Input 1
= 1“
2
Set by clicking on “Send”
3
Activate “Test and
Measurement”
4
Select „Noise Level“ and
start by clicking on „Start“
5
Normal Noise Level values
at antenna 1:
Average:
< 50mV
Difference (Max-Min):
< 30mV