Installation Manual
Table Of Contents
OBID i-scan
®
Installation ID ISC.ANT1700/740-A /-B
FEIG ELECTRONIC GmbH Page 30 of 40 M91201-0e-ID-B.doc
4.4.1 Reader Setting for Indicator
The ISOStart software can be used to set the Reader configuration so that relay X11 opens or
closes when a Transponder is read.
Step Action Note
1
Start ISOStart Software
2
Select “Configuration” and
click on “Read” to read the
complete configuration.
3
Operating Mode
Select Buffered Read Mode.
4
Digital IO:
Output Idle Mode: OFF
Idle Flash Mode: 1Hz
Setting Time:
with „Setting Time“ set
time of relay for alarm du-
ration.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign Relay 1 to antenna
1+2. „True“ means that
Relay 1 will be active at a
read transponder.
5
Set by clicking on „Apply“.
6
Transponder
ISO 15693 –Selection Mask
„Enable AFI“-Enabled
Enter desired value in
“AFI 1” field.
(e.g. 01)
6
Set by clicking on „Apply“










