User's Manual

IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Wave -A/-B
Page 13 of 80
Required components to setup a gate by using the Gate People Counter:
Number of
antennas
Antenna
People Counter (Optional)
ID ISC. ANT
1710/690 -A
ID ISC. ANT
1710/690 -B
ID ISC.
ANT.GPC
ID ISC.ANT.
GPC-E2
Note
2 Antennas
1
1
0
1 piece GPC included in
antenna type A
3 Antennas
1
2
0
1
1 piece GPC included in
antenna type A
4 Antennas
1
3
1
1
1 piece GPC included in
antenna type A
5 Antennas
1
4
1
2
Change to 8 Chanel Multi-
plexer, 1 piece GPC includ-
ed in antenna type A
6 Antennas
1
5
2
2
Change to 8 Chanel Multi-
plexer, 1 piece GPC includ-
ed in antenna type A
7 Antennas
1
6
2
3
Change to 8 Chanel Multi-
plexer, 1 piece GPC includ-
ed in antenna type A
Table 2 Required components for gates with People Counter
6 Installation and Wiring
NOTE:
Before installing the antennas please read 7.1 Project Notes Antenna. The spacing of the an-
tennas in a gate depends on the antenna configuration.
If multiple antennas or gates are connected to different readers, a minimum clearance of 8 m
must be kept between the antennas or gates. For shorter distances (1 m 8 m) the readers
must be synchronized. The synchronization of the readers (see application note N10311-xe-ID-
B.doc) is only possible in one of the Reader AutomaticModes.
At a distance below 1.5 m the antennas must be shielded from each other. Otherwise, the read
range will be significantly reduced.
The antennas must have a minimum distance of 20 cm to all larger metal parts! At a distance of
less than 50 cm between the antenna and metal parts the read range will be significantly reduced