User's Manual

IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Wave -A/-B
Page 20 of 80
If multiple gates are arranged at short distances (1-8m) from each other, they interfere with
each other. In this case, the readers for the individual gates must be synchronized and operat-
ed in one of the Reader Automatic Modes.
Fig. 11: Top view, capture area outside of the antenna gate
Direction
Minimum Distance
right, left (X=)
70 cm
front, behind (Y=)
30 cm
Table 3: Capture area, unintentional detection
To achieve three-dimensional reading of the tag in the reading area drawn above (
Fig. 10), the
following conditions must be fulfilled:
- The gate distance (GD) depends on the antenna configuration (see Table 5: ).
- The tags should be at least ISO card size (46 mm x 75 mm).
- The activation field strength of the tags should be less than or equal to 60 mA/m.
- The distance from tag to tag should be greater than 10 cm. If the tag to tag distance is reduced,
the gate distance GD must be reduced correspondingly. This applies in particular to distances
under 5 cm.
- The maximum number of tags (serial number or data) depends on the traverse speed with
which the tags are brought through the capture area of the gate (see Table 5: ). The number of
tags may be increased in the gate distance GD is correspondingly reduced and the maximum
speed adjusted accordingly.
- The antenna should be at least 50 cm away from metal parts.
- The minimum distance between the antennas of a gate and other antennas of RFID work
station or terminals (transmitting frequency 13,56 MHz) should be:
X
X
Y
Y