User's Manual

IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Wave -A/-B
Page 60 of 80
8.2.2 Configuration and Test in ISO-Host or Buffered Read Mode
Step
Action
Note
1
Select „Configuration“
2
Host Interface
Set RS 485 to “False” and
„Enable Termination
Resistors
The RS232/485 Settings
should be set to:
Busaddress=0,
Baudrate=38400 baud,
Parity = even ,
Number of Databits = 8,
Number of Stopbits = 1
3
Confirm with „Apply
4
Peripheral Devices
Gate People Counter
Mode
Enable GPC to
„New Generation
5
Confirm with „Apply
6
Peripheral Device
LED Controller:
Setting Time:
„Setting Time“ set the dura-
tion time for the alarm.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign
LED Bus Address 11 to
antenna 1.
LED Bus Address 12 to
antenna 2.
......... and so on.
„True“ means: LED with
Bus Address 11, 12, ... 17
will be active if the reader
read a valid transponder on
the corresponding antenna