User's Manual

IDENTIFICATION
ID ISC.ANT1710/690 Crystal
Gate Wave -A/-B
Page 75 of 80
10.2 People Counter ID ISC.ANT.GPC and ID ISC.ANT.GPC-E2
Mechanical Data
Housing
Printed Boards
Board Dimensions ( B x H x T )
People Counter Board
Radar Sensor Board
100 mm x 40 mm x 16 mm 1 mm
60 mm x 30mm x 25 mm 1 mm
Weight
ID ISC.ANT.GPC
ID ISC.ANT.GPC-E2
ca. 200 g / 250 g (0.55 lb) with packing
ca. 50 g / 100 g (0.22 lb) with packing
Mounting
No. of attaching points
People Counter: 4 / Radar Sensor: 2
Electrical Data
Supply Voltage
24 V 15 %
Power Consumption
max. 2 VA
Operating Frequency
24,125 GHz
RF-transmitting power
16 dBm (e.i.r.p.)
Temperature range
Operation
Storage
25 °C to +55 °C
25 °C to +85 °C
Functions
Number of Aisles per People Counter
Extension
1 or 2 aisle by using the second
radar module (ID ISC.ANT.GPC-E2)
up to 6 aisle =>2. People Counter
for the 3.+4. Aisle
3. People Counter
for the 5.+6. Aisle
Direction detection
Yes
Counter per aisle
1 x direction 1 / In
1 x direction 2 / Out
0..4 294 967 295
0..4 294 967 295