User's Manual

IDENTIFICATION
Installation
ID ISC.ANT1520/700-HPDA/-HPDB
FEIG ELECTRONIC GmbH Page 47 von 92 ID ISC.ANT1520700-HPDA-B
User Manual_M61113-0e-ID-
E.doc
6.4.3 Testing the performance
For testing the performance you must switch the reader to one of the Automatic Modes.
See 6.6
Activating the Automatic Mode
A read transponder will be displayed by a blue LED on the reader, the Alarm LED light of the
antenna and the Alarm sounder. See also 6.5.1
Reader Setting for Alarm Indicator
In this test the capture area of the gate antenna described in 6.1 Project Notes
is checked. For
other tags or other configurations the indicated ranges and read areas may differ accordingly.
Fig. 24: Performance Test of the gate antenna
The test begins by checking the read range outside the gate (see Fig. points and ), assuming
the configuration and locality permit it. If the tag is oriented parallel to the antenna at the outside, a
read range of 65 to 70 cm should be achieved.
The three tag orientations are checked inside the gate. This corresponds to the lines and
orientations
. Now slowly move the tag in the vertical and parallel direction with respect to
the antenna along the line
from one side to the other. The tag should always be read.
Then repeat this along the line in the vertical tag direction transverse to the antenna and on the
line
in the horizontal tag orientation. Here again the tag should always be read.
The tag should be read within the gate by moving in a horizontal line through the gate in all
three read orientations.