3 Operating and Display Elements
3.1 LEDs
Table 3-1 shows the LED configuration.
Abbreviation Description
LED V1 (green) "RUN-LED 1"
- Indicates proper running of the internal Reader software (DSP)
LED V2 (blue) Diagnostic 1: RF communication / EEPROM status
- Short flashing indicates errorless communication with a
transponder on the RF interface
- Flashes alternately with V1 after a reset following a software
update
- Flashes alternately with V1 in case of a data error when
reading the parameters after a reset
LED V3 (yellow) Diagnostic 2: Host communication
- Short flashing indicates sending of a protocol to the host on the
RS232/RS485 interface
LED V4 (yellow) Reserved
LED V5 (red) Diagnostic 4: RF warning
- Comes on during Reader initialization after power-on or after a
reset.
- Comes on when there is an error in the RF section of the
Reader. The error type can be read out via software over the
RS232/RS485 interface
LED V6 (green)
(only device
version with ACC)
"RUN-LED 2"
- Indicates proper running of the AC Controller
Table 3-1: LED configuration