5. Operating and Display Elements
5.1. Status LEDs
Table 12: Configuration of the LEDs
Green Yellow Red Description
ON OFF ON Boot sequence (ca.10s) after power on
FLASH OFF
OFF Normal Reader operation (without Host communication)
FLASH BLINKT OFF Reader receives a valid protocol from host
FLASH OFF ON RF Warning [0x84] (without host communication)
FLASH
(alternat-
ing)
OFF
FLASH
(alternat-
ing)
Firmware Activation necessary [0x17] /
Wrong Firmware [0x18]
FLASH
(synchro-
nous)
OFF
FLASH
(synchro-
nous)
RFC Hardware Error [0xF1]
OFF
FLASH
(synchro-
nous)
FLASH
(synchro-
nous)
Hardware Warning
(ACC EEPROM Error / RFC not detected)
FLASH OFF
FLASH
(fast)
USB Host Error
Firmware Update:
FLASH FLASH FLASH
Firmware transfer from host to reader
(Please do not switch off the reader or disconnect the interface cable)
(light in sequence)
FLASH FLASH FLASH
Firmware flash into EEPROM.
(Please do not switch off the reader or disconnect the interface cable)
synchronous
ANT 1- 4
RUN
Host
Communication
Warning
Input
Output