IDENTIFICATION Installation ID ISC.M02.M8 Note Copyright by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited.
IDENTIFICATION Installation ID ISC.M02.M8 Content ID ISC.M02.M8 1 1 Safety Instructions / Warning - Read before start-up ! 4 2 Performance Characteristics of the ID ISC.M02.M8 Reader Module 5 2.1 Performance Characteristics ...................................................................................5 2.2 Available module ......................................................................................................5 2.3 Available Accessories ....................................
IDENTIFICATION 1 Installation ID ISC.M02.M8 Safety Instructions / Warning - Read before start-up ! The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorised changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
IDENTIFICATION 2 Installation ID ISC.M02.M8 Performance Characteristics of the ID ISC.M02.M8 Reader Module 2.1 Performance Characteristics The ID ISC.M02.M8 reader module is designed for reading and writing passive transponders, socalled “Smart Labels”, with an operating frequency of 13.56 MHz according to the ISO15693 standard. It is suitable for any application in which short read ranges and small reader dimensions are required. The module has an integrated antenna multiplexer.
IDENTIFICATION 3 3.1 Installation ID ISC.M02.M8 Installation and wiring Dimensions Fig. 1 shows the dimensions of the ID ISC.M02.M8 Reader Module in mm. 87±0,3 80±0,3 65±0,3 5±0,3 2,54 16,5±0,3 5±0,3 2,5±0,6 0, 1 14,1±0,3 ,2± 45±0,3 X9 Ø4 50±0,3 4±0,3 Fig. 1: Dimension of the Readermodul ID ISC.M02.M8 FEIG ELECTRONIC GmbH Page 6 of 16 M02M8-IM-e_02.
IDENTIFICATION 3.2 Installation ID ISC.M02.M8 Wiring Figure 1 and Table 2 show the pin assignments for Terminal X9. The pin connector is designed for flat cable connection using a 5 pin multipoint socket connector type MTA 100 company AMP. X9 Pin-No.
IDENTIFICATION Installation ID ISC.M02.M8 3.2.2 RS232-LVTTL-Interface (3,3V) The length of the cable to the RS232 LVTTL interface should be kept as short as possible, and must in any case not exceed 1 m. The transmission parameters for the interface can be software-configured. Table 3 shows the standard parameters for the RS232 interface.
IDENTIFICATION Installation ID ISC.M02.M8 3.2.3 Connection of the external antennas Up to 8 external antennas can be connected. For the connection of the external antennas 8 antenna connectors (X1..X8 respectively A1..A8) are available. The connector type is U.FL-R-SMT from the company Hirose. . Alternatively a 16pin connector can be used for the connection of the antennas. Figure 1 shows the pin assignment. Figure 1: Antenna connector‘s Note: A coaxial cable, U.
IDENTIFICATION 3.3 Installation ID ISC.M02.M8 Installation notes The reader module has been designed for the installation in a device. 3.3.1 Mounting The reader module can be mounted by using 4mm (M4) screws. Component side: the maximum head diameter should not increase more than 8mm. Preferred no metallic screws should be used (DIN7985). Alternatively internal hexagon screws can be used (DIN 912). Component underside: conductive materials can have a diameter of 6mm.
IDENTIFICATION Installation ID ISC.M02.M8 3.3.3 EMC effects on cables In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an reader module into another device, be sure therefore that a clean, noise-free power supply is used. 3.3.
IDENTIFICATION 4 Installation ID ISC.M02.M8 Technical Data Mechanical Data Housing without housing Dimensions (W x H x D) 87 x 50 x 14,1 mm (3.43 x 1.97 x 0.56 inch) Weight 24 g Connector 5 Pin multipin connector Type MTA 100 AMP Electrical Data Supply voltage 24V DC ± 10% Current draw max. 100mA Power consumption max. 2 Watt Operating frequency 13,56 MHz Transmitting power 200mW ± 1dB Antenna connection up to 8 external Antennas (50Ohm) (Connection: U.
IDENTIFICATION Installation ID ISC.M02.M8 Ambient Conditions Temperature range -20°C to +70°C -40°C to +85°C - Operation - Storage Humidity (-4°F to 158°F) (-40°F to 185°F) 5 – 95% non condensing Applicable Norms Radio approval Europa EN 300 330 USA Kanada FCC 47 CFR Part 15 IC RSS-210 EMC EN 301 489 Safety EN 60950 EN 50364 Waste and Hazardous Substances WEEE - 2002/96/EC RoHS - 2011/65/EC FEIG ELECTRONIC GmbH Page 13 of 16 M02M8-IM-e_02.
IDENTIFICATION 5 5.1 Installation ID ISC.M02.M8 1. Approvals 1.1. Europa (CE) Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR60 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.feig.de/en/downloads-support/declarations-of-conformity.html Performance Classification according to ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 14 of 16 M02M8-IM-e_02.
IDENTIFICATION 5.2 Installation ID ISC.M02.M8 1.2. USA (FCC) and Canada (IC) Product name: ID ISC.M02.M8 FCC ID: PJMM02M8 IC: Notice for USA and Canada 6633A-M02M8 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
IDENTIFICATION Installation ID ISC.M02.M8 The manufacturer is obliged to test the terminal device together with the reader module according to the national FCC requirements according to 47 CFR Part15 §209 and §225 For this purpose the reader module must be set to normal operation, ScanMode.