INSTALLATION ® OBID megalock-l (2) (1) Fig. 1: megalock-l layout right (layout left = mirror image) (1) Recommended door hole diameter 23 mm (2) max. door thickness 21.5 mm Note final public 2003-05-13 M81291-7e-ID-B.
OBID® megalock-l Installation Copyright 1998 - 2003 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages.
OBID® megalock-l Installation Contents 1. Safety and warning notices – read before commissioning.......................................4 2. Basic functions of the megalock-l...............................................................................5 2.1. Locking the megalock-l .............................................................................................5 2.2. Unlocking the megalock-l..........................................................................................5 3.
OBID® megalock-l Installation 1. Safety and warning notices – read before commissioning • The device may only be used for the purpose intended by the manufacturer. • The operating instructions have to be handed out to every user and kept in an easily accessible place. • Unacceptable changes as well as the use of spare parts and special features which are not sold or recommended by the manufacturer, may cause fire, electric shocks and injuries.
OBID® megalock-l Installation 2. Basic functions of the megalock-l (1) Rotary knob: With integrated LED display (red / green) and antenna for exchange between megalock-l and megaKey. (2) Battery compartment: Use special screwdriver to open (Type: ID MS.SSD-A). 2.1. Locking the megalock-l 1. Push rotary knob megalock-l is activated for 8 sec. (no indicator) 2. Present megaKey: The green LED flashes for a max. of 8 sec.
OBID® megalock-l Installation 3. LED indicators OK (LED flashes green) • Action was successfully completed (e.g. megalock-l is locked or unlocked) megaKey not authorized (LED flashes red) Possible cause: • Handling error (actuation sequence incorrect). • Wrong megalock-l (megaKey is not assigned to this megalock-l or has already locked another megalock-l). • Group number of megalock-l and megaKey or MasterKey are different. • megaKey does not belong to the system (wrong System IDs).
OBID® megalock-l Installation 4. Installation Installing: The electronic cabinet lock megalock-l is attached on the inside of a cabinet door using four screws. Testing: After installing, check the function of the megalock-l using the TestKey. Applying the reference plate: Stick the user reference plate only to a flat, grease- and dust-free surface. Configuring: Once the installation work is complete and all the locks tested, they are configured using the SetupKey. 5. Commissioning 5.1.
OBID® megalock-l Installation 5.2. Configuring the megalock-l with the "SetupKey" The SetupKey is used to configure the System-ID, the cabinet number, the operating mode and the group number in the megalock-l. Only than can the megalock-l be used in the system. An already configured megalock-l will no longer accept the SetupKey. To change the configuration of a megalock-l, the latter must first have been cleared using a valid ResetKey. CAUTION: Use only a SetupKey having the correct Group No.
OBID® megalock-l Installation 5.3. Resetting a megalock-l with the "ResetKey" Clearing a megalock-l may be necessary for example if a mistake was made in initializing (e.g. wrong cabinet number) or if a megalock-l needs to have a different configuration. NOTE The ResetKey is only accepted by the megalock-l if it is unlocked! The megalock is reset in the following way: 1. Activate megalock (push rotary knob) 2.
OBID® megalock-l Installation 6. Battery The battery in the megalock-l is designed for at least 40 actuations daily within a period of 3 years. The time when the battery needs to be replaced will depend however on the self-discharging of the battery and by climatic effects, especially cold temperatures. To summarize, the time to replace the battery depends on the following factors: 1. the number of actuations, 2. how long the battery has been installed, and 3.
OBID® megalock-l Installation 8. Technical Data • Dimensions (W x H x D): 110 x 119 x 84 mm • Weight: approx. 350 g (incl. battery) • Enclosure rating IP 43 • Temperature range: Operating: Storage: 0 °C -25 °C to to 60 °C 60 °C Function and storage: 10 % to 90 % (non-condensing) • Relative humidity • Battery life expectancy • 3 years assuming 40 actuations daily • Unlocking is possible for 6 weeks after reaching battery alarm level • Compatible Transponder model OBID® ID DTx.
OBID® megalock-l Installation 9. Approval 9.1. Europe (CE) When properly used this radio equipment conforms to the basic requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/E6 of March 99. 9.2. USA (FCC) FCC ID: PJMMLL01 This device complies with Part 15 of the FCC Rules.