Instruction manual Digital Radar Motion Detector with Infrared Remote Control MWD BF FEIG ELECTRONIC GmbH Lange Straße 4 35781 Weilburg/Lahn 22.08.
MWD BF Instruction manual General Copyright 2002 by FEIG ELECTRONIC GmbH Lange Straße 4 D - 35781 Weilburg The indications made in these operating instructions may be altered without previous notice. With the edition of these instructions, all previous editions become void. Composition of the information given in this manual has been done to the best of our knowledge.
Instruction manual MWD BF Contents FUNCTIONAL DESCRIPTION.....................................................................................................4 2 INSTALLATION ....................................................................................................................5 2.1 Place of installation.........................................................................................................5 2.2 Mounting of the bracket ........................................................
MWD BF Instruction manual Functional description The MWD BF is a radar motion detector with direction identification, which has been especially designed for applications in the area of industrial gate- and barrier systems. In some cases, the operational parameters may also be adjusted with an infrared remote control. Motion detection is done according to the Doppler’s principle. The sensor sends out 24 GHz microwaves. These microwaves are reflected by objects in motion and thus their frequency changes.
Instruction manual 2 Installation 2.1 Place of installation MWD BF The device is centrally mounted above the area to be monitored. Both wall- and ceiling mountig are possible. The maximum mounting height is approx. 6m. Hints for planning and installation: • The device has to be mounted vibrationless. • In order to avoid incorrect release, there must not be any objects in motion within the radiation field. • There must not be any fluorescent tubes within the radiation field of the detector.
MWD BF Instruction manual Figure 1: Magnified diagram of the housing.
Instruction manual 3 MWD BF Adjustment and Initiation 12-27V AC 12-30V DC ~ Jumper Device address ~ Jumper/Resistor Relay hold time Connector DIP-Switch Direction mode O N IR-receiver for remote control Button a) Change value (short) b) Exit input mode (long) Button a) Change function (short) b) Exit input mode (long) LED red a) Object recognition normal mode b) Flash signals device address c) Flash signals current value LED yellow a) Ready to receive remote control b) Flash signals function
MWD BF 3.2 Instruction manual Device address In order to be able to adjust neighboring motion detectors with a remote control, an address may be assigned to each device in the range of 1-4. For this purpose, a jumper field is located above the DIP-switches. Address Jumper position 1 2 3 4 3.3 LED display Mode of operation Yellow LED – left side Red LED – right side object recognition off object identified adjustment with key button flash signals for function numbers flash signals acc.
Instruction manual MWD BF vehicles, fork-lift trucks with fabric rolls etc.) may lead to malfunctions if personal suppression is activated. 3.6 Adjustment with key buttons Operational parameters (sensitivity, personal suppression) may be adjusted with the buttons located at the right side of the horn antenna.
MWD BF Instruction manual 3.7.2 Selection of sensitivity After the device has been cleared, the sensitivity of the motion detector may be changed with the keys and . When the keys are pressed for the first time, the yellow LED indicates the number of the desired function with flash signals. The adjusted value is indicated by flash signals of the red LED. Sensitivity ranges from 1 to 15. Yellow LED Red LED Notice: flashes flashes 1x (function 1) 1 x acc.
Instruction manual MWD BF In order to change the angle of radiation, please loosen the lateral screws located between mounting bracket and housing. On both sides of the housing there are division marks in a 15° grid system. The size of the detection zone may change depending on the size and speed of the object to be detected. If the motion detector is mounted in a height of more than 4 meters and sensitivity is low, the detection zone for persons becomes very small. 3.
MWD BF 4 Instruction manual Technical Data Housing Dimensions (without cable) 132 x 155 x 58 mm Color black Housing plastic ASA Mounting bracket plastic ASA Cover plastic PC Weight (incl. mounting bracket) Protective system 0,3 kg IP 65 Supply voltage 12-27 V AC 12-30 V DC typ. 1,5 W max. 2,4 W Power consumption Operating temperature Storing temperature Air moisture -20 °C to +55 °C -30 °C to +75 °C < 95 % non fogging Frequency Transmitting power 24,125 GHz typ. 5 mW Output relay max.
Instruction manual 5 MWD BF Safety instructions • This device shall only be used for the purpose intended by the manufacturer. • The operating instructions have to be handed out to each user and accessible at any time. • Improper changes and spare parts resp. special features which are not sold or recommended by the manufacturer of the device may cause fires, electric shock and injuries. Such measures therefore lead to nonliability of the manufacturer and no guarantee will be given.
MWD BF 6 Instruction manual Type approval Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of article 3 and the other relevant provisions of the R&TTE guideline1999/5/EC dated March 99.
Instruction manual MWD BF USA (FCC) FCC ID: PJMMWDBF This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device.
MWD BF 7 Instruction manual Abstract Operating elements and pin configuration: 12-27V AC 12-30V DC ~ Jumper Device address ~ Jumper/Resistor Relay hold time Connector DIP-Switch Direction mode O N IR-receiver for remote control Button a) Change value (short) b) Exit input mode (long) Button a) Change function (short) b) Exit input mode (long) LED yellow a) Ready to receive remote control b) Flash signals function LED red a) Object recognition normal mode b) Flash signals device address c) Fl