Extension cable.
If the use of an extension cord
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool. Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
Recommended dimensions of extension cords
at an operating voltage of 120 V – single-
phase a. c., with only BOP6 (**), BOP10 (**),
BOP10-2 (**), BOP13-2 (**) connected:
Intended use of the power tool:
hand-held drill for drilling in metal, wood,
plastic, ceramics, and for tapping in weather-
protected environments using the application
tools and accessories recommended by FEIN.
Operation of the power tool off power generators.
Operating the power tool off
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
WARNING
Max. cable length, ft Max. cable length, m
≤ 100 100
–200
200
–300
≤ 30 30
– 60
60
–100
Min. conductor size
A.W.G.
Min. conductorcross-
section, mm
2
16 16 14 1.5 1.5 2.5