Outlet Box
Ceiling
Mounting Strap
Hex Nut
Glass Housing
Coupler
Long Threaded Pipe
Cap
Finial
Outlet Box Mouting Screws
Ground
Wire
6. To make electrical connections: Connect the white 
wire(s) from the fixture to the white wire of the outlet 
box. Connect the black wire(s) from the fixture to the 
black wire of the outlet box. NOTE: Black outlet box 
wire may be red, round & smooth and/or have copper 
conductor. White outlet box wire may be square & 
ridged and/or have a silver conductor.
7. Place pan thru short threaded pipe so pan sits 
flush against ceiling. Be sure all wires are inside 
pan. Secure pan to ceiling by fastening coupler 
onto short threaded pipe. Coupler must turn at least 3 
times, if it does not you must lengthen threaded pipe 
accordingly.
8 Bulb Fixture: Refer to relamping label found in pan for 
correct wattages.
9. Screw long threaded pipe into coupler until secure. 
Place glass housing over pan. Secure cap with finial.
1. If your are replacing an existing fixture, disconnect and 
remove the old fixture. Expose the supply wiring from 
the outlet box.
2. Screw short threaded pipe 3 complete turns into the 
mounting strap and lock in place with hex nut.
3. Fasten the mounting strap to the outlet box using the 
two screws supplied with the outlet box.
4. Spread the electrical wires so that the black wires are on
one side of the outlet box and the white wires are on the 
other side.
5. Mounting strap is provided with a green ground wire 
attached. Connect mounting strap ground wire to 
ground wire from outlet box wire with wire connector 
(not provided).
Never connect ground wire to black or white power supply 
wires
IMPORTANT
TURN OFF THE POWER AT THE MAIN FUSE OR CIRCUIT BREAKER BOX
BEFORE STARTING INSTALLATION
Short Threaded Pipe