Manual
09/00
IMPORTANT
TURN OFF POWER AT MAIN FUSE TO CIRCUIT
BREAKER BOX BEFORE STARTING INSTALLATION
1. Carefully unpack and identify all parts.
2. Remove roof by unfastening screws from roof. Slid
top threaded pipe thru top of roof and attach to finial.
Secure finial to top of roof by tighten hex nut to top of
roof. Make sure not to over tighten.
3. Install light bulb (not included). See relamping label,
located near socket, for type and maximum allowed
wattage.
4. Secure roof to main frame by reassembling screws to
roof.
5. Slip post cup over bottom threaded pipe. Slip washer
with ground wire, metal washer and rubber washer
over bottom threaded pipe, secure all with hex nut.
6. Electrical installation onto post: If you are
replacing and existing fixture, disconnect and
remove the old fixture.
A) Slip post cup over post. Mark position of
holes in post cup on post.
B) Remove post cup and expose the supply
wiring from above post. Drill 1/8" diameter
pilot holes in post at places where marked.
C) Make wire connections. (wire connectors not
provided). Refer to chart below for correct
connections. Wire supply wires to fixture
wires accordingly.
MURRAY FEISS
©FEISS INDUSTRIES
D) Connect ground wire from supply source to
fixture ground wire with connector. Never
connect ground wire to black or white power
supply wires. Carefully place wires inside
post.
E) Slip post cup onto post. Align holes in
post cup with holes in post. Attach post cup
to post with post cup screws.
Tracer Wire
*Note: When parallel wire (SPT 1 & SPT2)
is used. One wire is square shaped or
ridged and the other wire will be round
in shape or smooth. (See Illustration)
Connect Black or
Red Supply Wire to:
Black Fixture Wire or
*Parallel cord
(round & smooth)
Clear, Brown, Gold or Black
without tracer
Insulated wire
(other than green)
with copper conductor
Connect Black or
White Supply Wire to:
White Fixture Wire or
*Parallel cord
(square & ridged)
Clear, Brown, Gold or Black
without tracer
Insulated wire
(other than green)
with silver conductor
Finial
Top Threaded Pipe
Roof
Hex Nut
Lantern
Housing
Bottom Threaded
Pipe
Post Cup
Metal Washer
Washer with
Ground Wire
Ground Wire
Hex Nut
Fixture Wires
Supply wires
Post (Not Supplied)
Rubber Washer
Post Cup Screws
Roof Screws
Bulb (Not Supplied)