SDS

6 of 12
----------------------------------------------------------------------------------------------------------------------------------------------------------
VIII.
EXPOSURE
CONTROLS
/
PERSONAL
PROTECTION
----------------------------------------------------------------------------------------------------------------------------------------------------------
Threshold
Value
Limits
(TLV):
Chemical Name
Exposure Limits in Air (mg/cubic m)
ACGIH (TLV)
OSHA (PEL)
Glass
(Soda-Lime)
10.0
(2)
15.0
(2)
(1,4)
Mercury
0.025
0.1
Ceiling
(1,3)
Lead
Oxide
0.05
0.05
Aluminum
Oxide
10.0
(2)
15.0
(2)
(1,4,6)
Lead
Solder
(as
Pb)
0.05
0.05
(5)
Krypton-85
---
---
Fluorescent
Phosphor
10.0
(2)
15.0
(2)
May
contain:
(3)
Barium
Compounds
(as
Ba
dust)
0.5
0.5
(3)
Manganese
(as
dust)
0.2
5.0
Ceiling
(3)
Yttrium
Oxide
(as
Y
dust)
1.0
1.0
(1)
These
chemicals
are
subject
to
the
reporting
requirements
of
section
313
of
Title
III
of
the
Superfund
Amendments
and
Reauthorization
Act
of
1986
and
40
CFR
Part
372
(2)
Limits
as
nuisance
particulate
(3)
These
elements
are
contained
in
the
material
as
part
of
its
chemical
structure;
the
material
is
not
a mixture.
(4)
The
mercury
and
lead
in
this
product
are
substances
known
to
the
stat
of
California
to
cause reproductive
toxicity
if
ingested.
[California
Safe
Drinking
Water
and
Toxic
Enforcement
Act
of
1986 (Proposition
65).]
(5)
This
radioactive
isotope
is
found
in
the
glass
encapsulated
starting
switch
mounted
only
in
the
base of
CFLs.
(6)
This
material
is
found
only
on
the
base
of
the
CFL’s
ballast/adapter
unit
and
the
%
weight
is
relative
to
the
entire
lamp
&
ballast/adapter
unit.
Personal Protective Equipment:
OSHA
specified
cut
and
puncture-resistant
gloves
are
recommended
for dealing
with
broken
lamps.
Eye Protection:
OSHA
specified
safety
glasses,
goggles
or
face
shield
are
recommended
if
lamps
are bing
broken.
Skin Protection:
After
handling
broken
lamps,
wash
hands
and
face
thoroughly
before
eating,
drinking, smoking
or
handling
tobacco
products,
applying
cosmetics,
or
using
toilet
facilities.
Respiratory
Protection:
Use
appropriate
NIOSH
approved
respirator
if
airborne
dust
concentrations exceed
the
pertinent
PEL
or
TLV
limits.
All
appropriate
requirements
set
forth
in
29
CFR
1910.134
should be
met.
------------------------------------------------------------------------------------------------------------------------------
Product
Safety
Data
Sheet
for
FEIT
ELECTRIC
COMPANY
brand
Compact
Fluorescent
Lamps
SDS
No.
1.0
------------------------------------------------------------------------------------------------------------------------------