User's Manual

9 10
4.3 Cleaning mode (Deep cleaning )
For a correct tamping consistency ,daily cleaning of the
tamping base is recommended
4.3.1 Press clean button for 3 second ,the tamper base moves
down in cleaning position
4.3.2 Remove the silicone stopper
4.3.3 Unscrew the tamper base bolt by turning the allen key
counter-clockwise and remove the bolt Fig-7
4.3.4 Unscrew the tamper base by turning it counter - clockwise
Fig-8
4.3.5 Clean the tamper base using a brush or dry cloth
4.3.6 Screw the tamper base back by turning it clock wise
Fig-9
4.3.7 Screw the bolt back by turning the allen key clockwise
Fig-10
4.3.8 Place back the silicone stopper
4.3.9 Press clean button again to return the tamper base to its
idle position
Fig-6
1st PW the tamping
force is (e.g.) 5 kg
2nd PW the tamping
force is (e.g.) 20 kg
3rd PW the tamping
force is (e.g.) 30 kg
CLEANMODECLEANMODECLEANMODE
pressing clean button
to confirm to next step
pressing clean button
to confirm to next step
Pressing clean button
to confirm all data after
to next step
PW
U1
PW
U1
PW
U1
2nd tamping
time is 0.5 sec
1st tamping
time is 0.2 sec
3rd tamping
time is 1 sec
CLEANMODECLEANMODECLEANMODE
pressing clean button
to confirm to next step
pressing clean button
to confirm to next step
Pressing clean button
to confirm all data after
adjusting
100
ms
U1
100
ms
U1
100
ms
U1
CLEANMODE
100
ms
PWNet
U1 U2 U2
Part symbol
First set of user data
Second set of user data
Third set of user data
In pressing
Bluetooth link
PW
U1
U2
U3
Net
First tamping
Second tamping
Third tamping
Cleaning symbol
Time symbol
100
ms
Confirm /clean button
Fig-5
Decrease button
Increase button
CLEAN