Technical data

THERMAL RE-SET
The machine is supplied with a thermal re-set switch. The switch will activate
when the machine becomes too hot. This condition should not occur during
normal use. To re-set the switch:
Isolate the machine from the mains supply.
Safely support the machine - to access the underside.
Using a cross-head screwdriver, open the cover plate.
Using a suitable tool, insert the tool through the aperture and press the
metal switch until it snaps closed. The switch will close correctly, only if the
machine is cool enough.
Replace the cover plate and screws.
Power-on the machine.
TROUBLESHOOTING
Problem Possible cause Solution
No power on LED Machine is not switched on Switch on machine at rear next to plug inlet and at the wall socket
Ready light does not come on after a
long period
Machine is in a hot or humid area Move the machine to a cooler and dry area
Pouch does not completely seal the item
Item may be too thick to laminate Pass through the machine again
Temperature setting may be incorrect Check pouch thickness is correctly selected and pass through again
Pouch has waves or bubbles Temperature setting may be incorrect Check pouch thickness is correctly selected and pass through again
Pouch is lost in the machine Pouch is jammed
Select reverse button and pull out the item by hand. Check cooling
plate is correctly positioned.
Jamming
Pouch was used ‘open end’ first
Pouch was not centred on entry
Pouch was not straight upon entry
Empty pouch was used
Cooling plate not fixed correctly
Pouch is damaged after lamination Damaged rollers or adhesive on rollers Pass cleaning sheets through the machine to test and clean rollers
Temperature not increasing
Main fuse failure
Check and replace
Power cord not fitted correctly
Curled or burnt laminations Too hot Reduce temperature or increase speed
Soft or poor lamination Too cold Increase temperature or reduce speed
Rollers not running
Rollers too cold (< 60°c) Wait for rollers to warm-up
"STOP" button may be pressed Press "MOTOR" or "SPEED" button
Unstable lamination temperature Roller electric brush may be broken
Contact service engineer
Cannot select any Mode Circuit board error
Rollers not running & motor is running Loose circuit bolts on gear
Excessive noise Gears word or damaged
Master fuse keeps failing Damaged circuit board
7