Instructions

Ecosun A (mm) B (mm)
300 Basic 340 280
600 Basic
935 280
850 Basic
Ecosun X (mm) Y (mm) A (mm) B (mm) Thickness
300 Basic
592 592 340 355
30
600 Basic
1192 592 940 355
850 Basic
1192 800 940 355
1. Use
Flats, offices, schools, hospitals, shops, industry and agricultural premises, etc.
The panels can be installed on flammable materials.
2. Wiring
Power supply: 230V/50Hz
Protection class I
IP 44
The panel is fitted with a thermal fuse.
3. Installing
The panels are intended for vertical installation. In case of horizontal installation on the ceiling of a room, hang the panel
on a mounting frame, or using chains or cords.
The minimum distance of the panel front wall and lateral walls from inflammable objects is 10 cm.
Procedure — vertical mounting:
Mark the holes according to the table, drill out the holes, insert the dowels and drive the screw in to protrude
approx. 5 mm.
Always fix the panel on two upper locks, two lower locks serve to a reverse suspension of the panel.
Connect the lead-in cable to a fixed power distribution in accordance with the colour marking of wires.
Put the panel on the two upper locks.
Procedure – horizontal mounting
Position the mounting frame in the location where the panel is to be placed, using a pen, mark holes according to the
holes on the frame.
Drill the holes, insert the wall anchors and attach the mounting frame with the screws.
Connect the lead-in cable to the mains in accordance with the colour of the conductors.
Slide the panel into the mounting frame.
Fixing Frame