4. MAINTENANCE
Make sure that the plug is removed from
the mains when carrying out
maintenance work on the motor.
The machine has been designed to operate
over a long period of time with a minimum of
maintenance. Continuous satisfactory operation
depends upon proper machine care and regular
cleaning. Before interfering in any way whatsoever
withthecompressor,pleasemakesurethat:
• Theswitchbuttonisinthe“0”positionandthe
power plug is removed from the power socket
• Theairtankisfullydecompressed(both
pressure gauges must be pointed at 0 Bar)
Malfunction
Shouldthemachinefailtofunctioncorrectly,a
number of possible causes and the appropriate
solutionsaregivenbelow:
Air loss
• Maybecausedbyapoorsealofaconnection.
• Checkallairconnectionsbywettingthem
with a soapy water solution ( Never use the
solution nearby electric connections )
• Whenthetankisemptyandbeingfilled.
The user might hear a sisseling sound by
the pressure switch. This is normal and
will stop before the compressor reach a
pressure of 1.5 bar
• Checkifthedrainvalve(14)isclosedwell
The compressor will not start
• Ifthecompressorisdifficulttostart,check:
• whetherthevoltageofthemainscorre-
sponds to that on the specification plate
(fig. 10)
• whetherelectricalextensioncablesare
being used with a faulty core or length.
• whethertheoperatingenvironmentistoo
cold(below0°C).
• whetherthereiselectricitysupply(plug
properly connected, magneto-thermal
fuses not broken).
The compressor does not shut off
Ifthecompressordoesnotshutoffwhenthe
maximumpressurehasbeenreached,thesafety
valveofthetankwillbeactivated.Itisnecessary
to contact the nearest authorised Support Service
for the repair.
Repairs and servicing should only be
carried out by a qualified technician or
service firm.
Cleaning
Regularly clean the machine housing with a
softcloth,preferablyaftereachuse.Keepthe
ventilation slots free from dust and dirt.
Ifthedirtdoesnotcomeoffuseasoftcloth
moistened with soapy water. Never use solvents
suchaspetrol,alcohol,ammoniawater,etc.
These solvents may damage the plastic parts.
Drain the tank
Compressing air will cause water in the tank.
Regularly drain the water from the tank to prevent
tankcorrosion(fig16):
• Firstreducethepressureinthetanktill
aprroxially 2 bar by connecting and activating
an air tool .
• Thenslowlyturnthedrainvalve(14)onthe
lower side of the tank open.
• Thewaterinthetankwillnowleakoutofthe
tank
Take care when compressed air is in the tank
because the water can come out with some force.
Recommended pressure max. 1-2 Bar.
Clean the air filter
Itisrecommendedtodisassemblethesuction
filter every 50 operating hours and to clean the
filter element by blowing it with compressed air
(fig.15).Itisrecommendedthatthefilterelement
is replaced at least once a year if the compressor
is working in a clean environment; more often
if the environment in which the compressor is
situated is dusty.
Replacing/topping up oil
The compressor has been supplied with synthetic
oil“SAE10W30”.Itisrecommendtofully
replace the oil of the pump system within the first
100 operating hours.
• Unscrewthedrainplug(gauge)(13)onthe
sumplid,letalltheoilrunoutandscrewback
the plug (fig. 17).
• Filltheoilviatheupperholeofthesumplid