DOOR RELAY TIME
: Time for lock-release relay remains active (1-9s optional).
OPEN DOOR DELAY
: The time when the unlocked signal is sent to the start of the relay.
The delay time is useful when the lock is not close panel (0-9s optional).
DOOR ALARM: An alarm will be issued when the door still open after the normal opening
time exceeds the set time.
Disable,30s, 60s, 120s, 180s and 250s optional.
DOOR FORCED ALARM: An alarm will be issued when an abnormal way of opening the
door is detected.
EXT. UNLOCK:
Enable or disabled external relay unlock function.
Relay 1-4 DOOR RELAY TIME
: Time for lock-release relay remains active (1-9s optional).
Relay 1-4 OPEN DOOR DELAY
: The time delay between the unlock signal sent and the relay
activation. The delay time parameter is useful when the door lock is not close to the panel (0-
9s optional).
ADMIN CARD
: Master card registered to enroll additional prox cards. When there is no
management software enter 0000 if you do not know the ID of the admin card. The first prox
card detected by the reader will act as admin/master card the card of resident can be added
afterwards. If this method is used, register the resident proximity id numbers on the cards.
DISARM BY CARD: When the card open the door, the alarm status of monitor corresponding
unit can change to HOME mode.
GUEST CODE: No function now.
ACCESS PIN: Enable or disabled the activation of the relay for PIN code access.
UP to 8 different PIN codes per panel.
PIN length between 4 to 6 digits.
REMARK: Reference F01491 (4 relay module) must be connected to the RS485 port of the