5. Parameter channel
5−15
Festo P.BE−SPC200−COM−PDP−E N en 0901c
PNU 209
d
(D1
h
): Register
Description Register (R)
Permitted values −32768 ... +32767
Presetting 0
Data type Integer16
Unit
Subindices 1: Register 0
2: Register 1
3: Register 2
...
100: Register 99
Access rights Read: yes; write: yes
Task identifier 6, 7, 8, 9
Reply identifier
(positive)
4, 5, 6
Protected against
power failure
Yes