Owner's manual
1. Installation instructions for the DGCI or DDLI
1-7
Festo P .BE-SPC11-DGCI-EN en 1406d
Compressed air tubing and screw connectors ( 4 )
See system manual type P.BE-SPC11-SYS...
•
Arrange the tubing between the valve (MPYE-5-...) and
the drive (DGCI/DDLI) symmetrically.
Recommendation: tubing length = drive length
•
Cut the tubing and the connectors to the required length
as shown in the following table.
Horizontal mounting position
Drive length in
mm
ValvetypeMPYE-...
Screw connec tors for
Tube type
PUN
MPYE-... DGCI/DDLI-...
DGCI-18-...
100 ... 300 MPYE-5-M5-010B QSM-M5-6 QSM-M5-6 PUN-6x1
360 ... 1750 MPYE-5-1/8-LF-010B QS-1/8-6 QSM-M5-6 PUN-6x1
2000 MPYE-5-1/8-HF-010B QS-1/8-6 QSM-M5-6 PU N-6x1
DGCI/DDLI-25-...
100 ... 160 MPYE-5-1/8-LF-010B QS-1/8-6 QS-1/8-6 PUN-6x1
225 ... 300 MPYE-5-1/8-LF-010B QS-1/8-8 QS-1/8-8 PUN-8x1,25
360 ... 2000 MPYE-5-1/8-HF-010B QS-1/8-8 QS-1/8-8 PUN-8x1,25
DGCI/DDLI-32-...
100 MPYE-5-1/8-LF-010B QS-1/8-6 QS-1/8-6 PUN-6x1
160 ... 1000 MPYE-5-1/8-HF-010B QS-1/8-8 QS-1/8-8 PUN-8x1,25
1250 ... 2000 MPYE-5-1/4-010B QS-1/4-8 QS-1/8-8 PUN-8x1,25
DGCI/DDLI-40-...
100 ... 500 MPYE-5-1/8-HF-010B QS-1/8-8 QS-1/4-8 PUN-8x1,25
600 ... 750 MPYE-5-1/4-010B QS-1/4-8 QS-1/4-8 PUN-8x1,25
850 ... 2000 MPYE-5-1/4-010B QS-1/4-10 QS-1/4-10 PUN-10x1,5