2. Parameters of the SPC11 for the DGCI or DDLI
2-3
Festo P .BE-SPC11-DGCI-EN en 1406d
2.1 SPC11 parameters
Warning
Incorrectly set parameters can damage the fixed stops and
the drive.
Be very careful when setting the parameters.
The SPC11 must be familiar with certain conditions of use.
These conditions of use are described by the follow i ng three
parameters, which must be entered directly on the SPC11:
Parameters
Description
Amplification stage Influences the acc eleration behaviour of the
drive
Cushioning stage Influences the retracting behaviour when
moving to the end positions and intermedi-
ate positions.
System parameters Characteristic value for the structure of the
drive
You can set the parameters with the buttons on the SPC11
(see System Manual). Vali d parameters for operating the
SPC11 with drive type DGCI/DDLI can be found in section 2.3.
These parameters are matched exactly to the specified com-
binations of drives, valves and mass loads.