User Manual
3. Installation
3-27
Festo P.BE-SPC11-SYS-EN en 1406e
Outputs on the 15-pin “Control” plug (O = output)
Pin
Pin assignment and core colours
Description
9 O5 – Error
1)
black Factory setting:
– Provides a 1-signal when an error occurs
(see chapter 5).
– Provides a 0-signal in the normal opera ting state
10 O4 –P.04
2)
violet Factory setting:
– Supplies a 1-signal if the moveable mass is in
the taught intermediate position P.04.
– Supplies a 1-signal for 50 ms if intermediate
position P.04 is overrun.
11 O3 P.0 3 grey-pink – Supplies a 1-signal if the moveable mass is in
the taught intermediate position P.03.
– Supplies a 1-signal for 50 ms if intermediate
position P.03 is overrun.
12 O2 P.0 2 red-blue – Supplies a 1-signal if the moveable mass is in
end position P.02.
13 O1 P.0 1 white-green – Supplies a 1-signal if the moveable mass is in
end position P.01 (on the side with the electrical
connection for the potentiometer).
1)
Function of O5 can be configured (see section 4.2.3); Error (fac tory setting) or Ready
2)
Function of O4 can be c onfigured (see section 4.2.3); P.04 ( factory setting) or Stop
Linevoltageonthe15-pin“Control”plug
Pin
Pin assignment and core colours
Description
14 – 0V brown-green 0V
15 – 24 V s upply white-yellow DC +24 V (tolerance -10 % to + 25 %)