Operation Manual

C 12 Li, C 15 Li
15
GB
An
acoustic signal
sounds when the preset torque
is reached and the machine then switches off. You
must release and press the ON/OFF switch
[1-9]
again to start the machine.
7.4 Drilling
Adjust the switch so that its marking
[1-7]
faces
the drilling symbol
[1-5]
= maximum torque.
8 Tool holder, attachments
8.1 CENTROTEC tool chuck [4]
Quick change of tools with CENTROTEC shaft
Only clamp CENTROTEC tools in CENTRO-
TEC tool chucks.
Wear gloves when replacing!
8.2 Chuck BF-FX [5]
For clamping drill bits and bits with max. shaft di-
ameter of 13 mm.
Clamp tool centrally in the chuck.
8.3 Angle attachment DD-AS [6]
Drilling and screwing at right angle to machine
(partly as an accessory).
8.4 Eccentric attachment DD-ES [7]
Screwdriving near edges with bits according to ISO
1173 (partly as accessory).
8.5 Tool holder in the drill spindle [8]
Bits can be inserted directly into the hexagon sock-
et holder of the drill spindle.
9 Working with the machine
9.1 On/Off switch [1-9]
Press = ON, release = OFF
The speed of the machine depends on how far
the on/off switch is pressed in.
The LED bulb
[1-3]
lights up when the ON/OFF
switch is pressed
[1-9]
.
9.2 Bit depot [1-2]
Magnetic, for storing bits and bit holders.
9.3 Acoustic warning signals
Acoustic warning signals sound and the machine
switches off in the following operating states:
10 Service and maintenance
Observe the following instructions:
Keep the air slits on the machine and the charger
free and clean to ensure adequate cooling.
Keep the contacts on the machine, charger and
battery pack clean.
Information on battery packs
Where possible, store the battery pack in a cool,
dry place at a temperature between 5 °C and 25
°C.
Battery packs are most efficient at temperatures
between 20 °C and 30 °C.
Protect the battery pack from moisture, water
and heat.
Significantly shorter operating times after each
charge indicate that the battery pack is worn and
should be replaced with a new one.
The LiIon battery pack is fully compatible with the
charger! Integrated electronics prevent over-
loading and overheating during the charging pro-
cess.
Do not leave flat battery packs in a charger dis-
connected from the mains power supply for lon-
ger than one month. There is a risk of total
discharge and the maximum power of the battery
pack may decrease.
Store the battery pack in its packaging to reduce
the risk of short circuits..
If LiIon battery packs are to be stored for long pe-
riods without use, they should be charged to 40 %
capacity (approx. 15 mins. charging period).
11 Accessories
The order numbers of the accessories and tools can
be found in the Festool catalogue or on the Internet
under "www.festool.com".
WARNING
Risk of injury, electric shock
Always disconnect the battery pack before any
type of work on the machine!
Battery flat or machine over-
loaded.
Change the battery.
Place the machine under reduced
stress.
Machine is overheating.
You must allow the machine to
cool beforeusing again.
LiIon battery pack is faulty or has
overheated.
Once the battery pack has cooled,
perform a functional check using
the charger.