6 Operation
6.1 Initial operation
X
Open the locking clips [2-2] and remove
the top section of the machine[2-1].
X
Remove the accessories from the dust
container [2-3] and the packaging!
X
Insert a filter bag in the dust container
that fulfils statutory requirements (see
chapter 7.8).
X
Replace the top section [2-1] and close
the locking clips [2-2].
X
Attach the cable holder to the rear of the
mobile dust extractor (see Fig. [3]).
X
Only CTM 48 E LE EC:
Insert the sealing
plug [1-1] on the panel (see Fig. [1] ).
X
Connect the suction hose to the machine.
6.2 Switch on/off
X
Insert the plug into an earthed socket.
The switch [1-9] serves as an on/off switch.
Switch position "0"
Appliance socket [1-11] is disconnected from
the power, mobile dust extractor is switched
off.
"MAN" switch position
Appliance socket [1-11] is connected to the
power, the mobile dust extractor starts.
"Auto" switch position
Appliance socket [1-11] is connected to the
power, the mobile dust extractor starts when
the connected tool is switched on.
7 Settings
7.1 Adjusting the hose diameter
(only CTM 48 E LE EC)
X
Adjust the hose diameter adjuster [1-8]
to match the diameter of the connected
hose.
L
The monitoring devices will measure the
air speed in the extractor hose correctly
as a result (see chapter 7.9).
7.2 Connecting electric power tools
X
Connect the electric power tool to the ap-
pliance socket [1-11].
7.3 Connecting pneumatic tools
With the compressed air module [1-3], the
automatic switch-on function for the mobile
dust extractor also works in conjunction with
air tools.
We also recommend installing the VE service
unit (495886). The service unit filters and lu-
bricates the compressed air and enables an
adjustment of the air pressure. An IAS
adapter (454757) is available to connect Fes-
tool air tools to the IAS system.
The operating pressure of the tool must be 6
bar for the automatic switch-on unit to func-
tion correctly.
WARNING
Unauthorised voltage or frequency!
Risk of accident
X
The mains voltage and the frequency of
the power source must correspond with
the specifications on the machine's name
plate.
X
In North America, only Festool machines
with the voltage specifications 120 V/60
Hz may be used.
CAUTION
Risk of injury from tools starting up un-
expectedly
X
Before setting the switch to the "AUTO" or
"MAN" position, make sure that the con-
nected tool is switched off.
WARNING
Risk of injury
X
Observe the maximum connected loads
for the appliance socket (see chapter
"Technical data").
X
Make sure that the power tool is switched
off before connecting or disconnecting.
WARNING
Risk of injury
X
Make sure that the pneumatic tool is
switched off before connecting or discon-
necting.