1Symbols
2 Technical data
3 Machine features
The specified illustrations appear at the be-
ginning of the Operating Instructions.
4 Intended use
Charger TCL 3 is suitable for
charging battery packs: Protool BP, Festool
BPS and BPC (NiMH, NiCd, li-ion are recog-
nised automatically.)
– internal use only.
The user is liable for improper or non-
intended use.
5 Safety instructions
Warning! Read all safety warnings
and all instructions.
Failure to follow the
warnings and instructions may result in elec-
tric shock, fire and/or serious injury.
Save all warnings and instructions for
future reference.
The charger and power tool are not in-
tended for use by persons (including
children) with limited physical, senso-
ry or mental ability or without suffi-
cient experience and/or knowledge,
unless they are supervised by a per-
son responsible for their safety or
have been instructed on how the
charger or power tool is to be
used.
Children should always be super-
vised to ensure that they do not play with
the charger or the power tools.
Do not open the battery pack or the charger!
Prevent metal parts (e.g. metal chips) or
fluids from entering the charger!
– Do not use battery packs or chargers from
other manufacturers!
– Protect the machine from moisture.
Protect the cable from heat, oil and sharp
edges.
Check the plug and the cable regularly and
should either become damaged, have
them replaced by an authorised after-sales
service workshop.
Warning of general danger
Risk of electric shock
Read the Operating Instructions/
Notes!
Do not throw in the household waste.
Charger TCL 3
Mains voltage (input) 220 - 240 V ~
Mains frequency 50/60 Hz
Charging voltage (output) 10.8 - 18 V=
Rapid charging max. 3 A
Conservation charging,
intermittent (NiCd, NiMH)
approx. 0.06 A
Charging times for BP, BPS
and BPC battery packs
Li-ion 1.5 Ah, 80 %/100 % approx. 25/35
min.
Li-ion 3.0 Ah, 80 %/100 % approx. 55/70
min.
NiMH 3.0 Ah approx. 70
min.
NiMH 2.0 Ah approx. 50
min.
NiCd 1.3 Ah approx. 25
min.
NiCd 2.4 Ah approx. 50
min.
Permitted operating tem-
perature range
-5 °C to
+4C
Temperature monitoring with NTC resis-
tor
[1-1]
Holder for battery pack
[1-2]
LED-Display
[1-3]
Cable holder
[1-4]
Battery pack
[4]
Wall mount