1Symbols
2 Technical data
3 Machine features
The specified illustrations appear at the be-
ginning of the Operating Instructions.
4 Intended use
Charger TCL 3 is suitable for
– charging battery packs: Protool BP, Festool
BPS and BPC (NiMH, NiCd, li-ion are recog-
nised automatically.)
– internal use only.
The user is liable for improper or non-
intended use.
5 Safety instructions
Warning! Read all safety warnings
and all instructions.
Failure to follow the
warnings and instructions may result in elec-
tric shock, fire and/or serious injury.
Save all warnings and instructions for
future reference.
–
The charger and power tool are not in-
tended for use by persons (including
children) with limited physical, senso-
ry or mental ability or without suffi-
cient experience and/or knowledge,
unless they are supervised by a per-
son responsible for their safety or
have been instructed on how the
charger or power tool is to be
used.
Children should always be super-
vised to ensure that they do not play with
the charger or the power tools.
– Do not open the battery pack or the charger!
– Prevent metal parts (e.g. metal chips) or
fluids from entering the charger!
– Do not use battery packs or chargers from
other manufacturers!
– Protect the machine from moisture.
– Protect the cable from heat, oil and sharp
edges.
– Check the plug and the cable regularly and
should either become damaged, have
them replaced by an authorised after-sales
service workshop.
Warning of general danger
Risk of electric shock
Read the Operating Instructions/
Notes!
Do not throw in the household waste.
Charger TCL 3
Mains voltage (input) 220 - 240 V ~
Mains frequency 50/60 Hz
Charging voltage (output) 10.8 - 18 V=
Rapid charging max. 3 A
Conservation charging,
intermittent (NiCd, NiMH)
approx. 0.06 A
Charging times for BP, BPS
and BPC battery packs
Li-ion 1.5 Ah, 80 %/100 % approx. 25/35
min.
Li-ion 3.0 Ah, 80 %/100 % approx. 55/70
min.
NiMH 3.0 Ah approx. 70
min.
NiMH 2.0 Ah approx. 50
min.
NiCd 1.3 Ah approx. 25
min.
NiCd 2.4 Ah approx. 50
min.
Permitted operating tem-
perature range
-5 °C to
+45°C
Temperature monitoring with NTC resis-
tor
[1-1]
Holder for battery pack
[1-2]
LED-Display
[1-3]
Cable holder
[1-4]
Battery pack
[4]
Wall mount